Miscellaneous Tower Hardware
เราผู้จำหน่าย
ผลิตภัณฑ์ Fastener (สลักภัณฑ์) หลายประเภท
โบล์ต น๊อต สกรู แหวน รีเวท ปิ๊น คลิป ฯลฯ ทั้งตามมาตรฐานสากล
และผลิตเฉพาะตามแบบที่กำหนด |
Material : Carbon steel,
Stainless Steel , Brass ,Copper etc.
Standard :
According to ISO, DIN, ANSI, JIS, ASTM etc.
Finish : Black, Plain, Zinc, Nikel, Chromium, Dacromet,Hot-dip Galvanized
,(comply RoHS)
We supply our
customers superior quality products, like as HEX HEAD BOLTS, CARRIAGE
BOLTS, HEX NUTS, HEAVY HEX NUTS, STUD BOLTS, STUDDING, THREADED ROD AND WASHERS.
MaterialDescription
Steel grade 2
Zinc
plated low carbon steel. Best
for general hardware use where high strength is not required.
Steel grade 5
Made from medium carbon steel, tempered and
zinc plated. Best for automotive use and other areas where higher strength is
desired.
Steel grade 8
Made from medium carbon alloy steel, tempered,
and zinc plated. Best suited for applications where high strength and hardness
is required.
Stainless steel 18-8
Stainless steel 18-8 is an alloy of steel with
high corrosion resistance. Stainless has become the material of choice for
exterior and most marine applications.
Silicon Bronze
Bronze is an alloy of copper with greater
strength and corrosion resistance than brass. Most commonly used in wood boat
building and restoration.
Hot dipped galvanized
Hot dipped galvanized fasteners are much more
corrosion resistant than zinc plated fasteners. Due to the thickness of the
galvanized coating, galvanized bolts will only work with galvanized nuts. For
exterior and coastal area use. (ASTM A153)
Grade 5 chrome
A grade 5 fastener with a bright mirror-like
finish providing sharp looks for a variety of applications.

|
Price List of bolts & nuts,
Turnbuckles , Shackles, L-Bolts , U-bolts |
|
Description |
Unit price Baht. |
Remarks |
| Bolts
m12x45 (1-nut, 1washer, 1 spring washer) |
8.50 |
Hot dip Galvanized Grade
8.8 |
| Bolts
m12x35 (1-nut, 1washer, 1 spring washer) |
7.50 |
Hot dip Galvanized Grade
8.8 |
| Bolts
m16x60 (2-nut, 1washer, 1 spring washer) |
25.50 |
Hot dip Galvanized Grade
8.8 |
|
Bolts
m16x90 (2-nut, 1washer, 1 spring washer) |
35.50 |
Hot dip Galvanized Grade
8.8 |
| Bolt & Nuts
m16x55 (1Nuts+1Washer+1Spring Washer) |
24.00 |
Hot dip Galvanized Grade
8.8 |
|
Bolt & Nuts m12x80
(1Nuts+1Washer+1Spring Washer) |
16.80 |
Hot dip Galvanized Grade
8.8 |
| Bolt & Nuts
m12x30 (1Nuts+ 1Washer+1Spring Washer) |
6.00 |
Hot dip Galvanized Grade
8.8 |
| Bolt & Nuts
m12x200 (1Nuts+ 1 Washer+1Spring Washer) |
42.00 |
Hot dip Galvanized Grade
8.8 |
| Bolt
M24*130 (2Nuts+1Washer+1Spring Washer) |
80.00 |
Hot dip Galvanized Grade
8.8 |
| Bolt
M22*125 (2Nuts+1Washer+1Spring Washer) |
68.00 |
Hot dip Galvanized Grade
8.8 |
|
Bolt M22*85
(2Nuts+1Washer+1Spring Washer) |
66.00 |
Hot dip Galvanized Grade
8.8 |
| Bolt M22*80
(2Nuts+1Washer+1Spring Washer) |
65.00 |
Hot dip Galvanized Grade
8.8 |
| Bolt M22*75
(2Nuts+1Washer+1Spring Washer) |
64.00 |
Hot dip Galvanized Grade
8.8 |
| Bolt
M20*120 (2Nuts+1Washer+1Spring Washer) |
48.50 |
Hot dip Galvanized Grade
8.8 |
| Bolt
M20*100 (2Nuts+1Washer+1Spring Washer) |
44.50 |
Hot dip Galvanized Grade
8.8 |
| Bolt M20*90
(2Nuts+1Washer+1Spring Washer) |
43.50 |
Hot dip Galvanized Grade
8.8 |
| Bolt M20*80
(2Nuts+1Washer+1Spring Washer) |
42.00 |
Hot dip Galvanized Grade
8.8 |
| Bolt M16*80
(2Nuts+1Washer+1Spring Washer) |
25.00 |
Hot dip Galvanized Grade
8.8 |
| Bolt M16*65
(2Nuts+1Washer+1Spring Washer) |
23.00 |
Hot dip Galvanized Grade
8.8 |
| Bolt 16*50
(2Nuts+1Washer+1Spring Washer) |
20.50 |
Hot dip Galvanized Grade
8.8 |
| Bolt M12*45
(1Nuts+1Washer+1Spring Washer) |
8.50 |
Hot dip Galvanized Grade
8.8 |
| Bolt M12*40
(1Nuts+1Washer+1Spring Washer) |
8.0 |
Hot dip Galvanized Grade
8.8 |
|
U-Bolts
m12 for pipe OD. 89.1 (1-nut, 1washer, 1 spring washer) |
38.00 |
Hot dip Galvanized Grade
8.8 |
|
U-Bolts m12 for pipe OD. 76.3 (1-nut, 1washer, 1 spring washer) |
33.50 |
Hot dip Galvanized Grade
8.8 |
|
U-Bolts m 12 for pipe OD. 60.5 (1-nut, 1washer, 1 spring washer) |
29.00 |
Hot dip Galvanized Grade
8.8 |
|
U-Bolts
m 9 for pipe OD. 48.6 (1-nut, 1washer, 1 spring washer) |
17.50 |
Hot dip Galvanized Grade
8.8 |
|
U-Bolts m 9 for pipe OD. 42.7 (1-nut, 1washer, 1 spring washer) |
16.50 |
Hot dip Galvanized Grade
8.8 |
|
U-Bolts m 9 for pipe OD. 34 (1-nut, 1washer, 1 spring washer) |
15.00 |
Hot dip Galvanized Grade
8.8 |
|
Cable clamp (wire
–grip) for ˝” cable |
16.50 |
Hot dip Galvanized Grade
8.8 |
| USA.Type
1/2*12 turnbuckle Eye & Jaw |
150.00 |
Hot dip Galvanized Grade
8.8 |
| US Type,
5/8*12" WLL=1.589ton BLL=5 times of WLL |
265.00 |
Hot dip Galvanized Grade
8.8 |
|
G-2130,Shackle ,Omega 5/8" WLL=3.25TON BLL=6*WLL |
98.00 |
Hot dip Galvanized Grade
8.8 |
| L-bolt Long
1000 thread length 150 (with 3Nuts + 1 W+1SW) |
275.00 |
Hot dip Galvanized Grade
8.8 |
| J-bolt
m12x30 |
78.00 |
Hot dip Galvanized Grade
8.8 |
| Lbolt
M20*1000 |
285.00 |
Hot dip Galvanized Grade
8.8 |
| ****
Note : price is subject to be changed without prior notice. |
Guy
Wire
Master Tower
supply 1/4",5/16" 3/8"&1/2" EHS galvanized steel wire is used for guying of
guyed-towers. Breaking strength for 3/16"EHS is 3990 pounds; 1/4"EHS is rated
6000 pounds.
Cab le
Clamps
Three
cable clamps are used to terminate guy wires. Available in four sizes: 3/16",
1/4", 5/16", and 3/8". These cable
clamps are constructed of electroplated steel or hot dip galvanized as your
requirement.
Thimbles

Thimbles
prevent the crimping of guy wire and preformed guy grip terminations. They are
used one size larger than the guy wire when terminated with cable clamps, or two
sizes larger than the guy wire when terminated with guy grips. Available in
three sizes: 1/4", 5/16", 3/8". Made of galvanized steel.
Preformed™ Big-Grip dead-ends

Preformed
Big-Grip dead-ends are used to quickly terminate guy wires, replacing cable
clamps. Available in 3/16", 1/4", and 5/16" sizes. Constructed of galvanized
steel.
Shackles
Galvanised with Screwed Collar Pin.
|
SWL TonnesBody
d
mm |
SWL TonnesD
mm |
SWL TonnesW
mm |
SWL TonnesS
mm |
SWL TonnesWeight
kgs/100 |
|
|
|
5 |
5 |
10 |
20 |
1.80 |
|
6 |
6 |
12 |
24 |
3.00 |
|
8 |
8 |
16 |
32 |
6.50 |
|
10 |
10 |
20 |
40 |
11.50 |
|
11 |
11 |
22 |
44 |
16.50 |
|
12 |
12 |
24 |
48 |
22.70 |
|
16 |
16 |
32 |
64 |
54.30 |
|
20 |
20 |
40 |
80 |
100.00" |
|
22 |
22 |
44 |
88 |
141.00 |
|
25 |
25 |
48 |
96 |
228.00 |
Bolts&Nuts

HEXAGON HEAD BOLTS
REFERENCE : DIN 931 PART1
MECHANICAL PROPERTIES : PROPERTY CLASS 8.8
METRIC COARSE THREAD
|
THREAD SIZE |
M5 |
M6 |
M8 |
M10 |
M12 |
M14 |
M16 |
M18 |
M20 |
M22 |
M24 |
M27 |
M30 |
M33 |
M36 |
|
Pitch
|
0.8 |
1.0 |
1.25 |
1.5 |
1.75 |
2.0 |
2.0 |
2.5 |
2.5 |
2.5 |
3.0 |
3.0 |
3.5 |
3.5 |
4.0 |
|
b
|
16 |
18 |
22 |
26 |
30 |
34 |
38 |
42 |
46 |
50 |
54 |
60 |
66 |
72 |
78 |
|
c
|
min |
0.15 |
0.15 |
0.15 |
0.15 |
0.15 |
0.15 |
0.2 |
0.2 |
0.2 |
0.2 |
0.2 |
0.2 |
0.2 |
0.2 |
0.2 |
|
max |
0.5 |
0.5 |
0.6 |
0..6 |
0.6 |
0.6 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
|
min
d
w
|
6.9 |
8.9 |
11.6 |
15.6 |
17.4 |
20.5 |
22.5 |
25.3 |
26.2 |
30 |
33.6 |
38 |
42.7 |
46.6 |
51.1 |
|
min
e
|
8.79 |
11.05 |
14.38 |
18.9 |
21.1 |
24.49 |
26.75 |
30.14 |
33.53 |
35.72 |
39.98 |
45.2 |
50.85 |
55.37 |
60.79 |
|
k
|
specific |
3.5 |
4.0 |
5.3 |
6.4 |
7.5 |
8.8 |
10 |
11.5 |
12.5 |
14 |
15 |
17 |
18.7 |
21 |
22.5 |
|
min |
3.35 |
3.85 |
5.15 |
6.22 |
7.32 |
8.62 |
9.82 |
11.28 |
12.23 |
13.78 |
14.78 |
16.65 |
18.28 |
21.58 |
22.08 |
|
max |
3.65 |
4.15 |
5.45 |
6.58 |
7.68 |
8.93 |
10.18 |
11.72 |
12.72 |
14.22 |
15.22 |
17.35 |
19.12 |
21.42 |
22.92 |
|
min
r
|
0.2 |
0.25 |
0.4 |
0.4 |
0.6 |
0.6 |
0.6 |
0.6 |
0.8 |
0.8 |
0.8 |
1.0 |
1.0 |
1.0 |
1.0 |
|
s
|
max |
8 |
10 |
13 |
17 |
19 |
22 |
24 |
27 |
30 |
32 |
36 |
41 |
46 |
50 |
55 |
|
min |
7.78 |
9.78 |
12.73 |
16.73 |
18.67 |
21.67 |
23.67 |
26.67 |
29.67 |
31.61 |
35.33 |
40.0 |
45.0 |
49.0 |
53.8 |
|
|
|
|
Turnbuckles
Turnbuckles are used to tension guy wires. They are available in eye & eye, or
eye & jaw formats, in 3/8" x 6", 1/2" x 9" 1/2" x 12", and 5/8" x 12" sizes.
Ceramic Strain Insulators
Insulators are used to isolate guy wires into nonresonant lengths. The 500D can
be used for 3/16"EHS, when terminated with cable clamps, and measures 2-1/4"
long by 1-1/2" in diameter. The 500D is com monly
referred to as an "egg insulator". The 502 is required for 1/4"EHS, or when
using guy grips with either wire size, and measures 3-1/2" long, 2-1/2" in
diameter. The 504 is for use with 5/16"EHS guywire, and measure 4-1/2" long,
2-7/8" in diameter.
| |
Exothermic welding
"An
exothermic connection is actually a molecular bond formed between 2
metals such as copper and steel. Copper oxide and aluminum are combined
and ignited. The result is an exothermic reaction that products molten
copper and aluminum oxide slag. The molten copper melts the objects
being connected together forming the molecular bond. This bond will not
loosen overtime or deteriorate with age. The connection's current
carrying capability is to that which it is being connected. In other
words, there is no increase in resistance in an exothermically welded
connection as there is in most pressure connections."
|
|
TOWER CLIMBING AND FALL PROTECTION

Fall prevention systems are an essential
component in tower planning, construction and use. It is equally essential to
upgrade the safety systems of older towers to current standards. Workers who
construct and maintain communications towers and other high structures are
always at risk of a fall, particularly when working in wind or inclement
weather. Enforcement of OSHA/CLC government regulations for worker safety at
heights is becoming more stringent. OSHA mandates that some form of fall
protection be supplied to employees who work at heights of 6 ft or more.
LED Warning Light (Obstruction Light)
ไฟสัญญาณเตือนการบิน
MASTER LAMP:
MLED_P.T.C.01 ไฟสัญญาณเตือนการบิน แบบ
LED
Special Price =
4,500.-Bht.
Specification
This subsection
provides specification for the Low Intensity Aviation Obstruction Light.
Rated Lamp life
The rated lamp
life for Low Intensity Aviation Obstruction Light is approximately 50,000 hours.
Environmental Operating
Conditions
The Low Intensity
Aviation Obstruction Light is designed to operate under the conditions presented
below for temperature, relative humidity, and wind.
Temperature
-20°C t0 + 60°C
Salient
Features of system
1.
Low intensity as per ICAO
2.
(International Civil
Aviation Organization) and FAA (Federation Aviation Administration) standard.
3.
Easy installation.
4.
Surge protection from
external atmospheric conditions.
5.
Self-protection of
equipment and personnel on work.
6.
Omni-directional LED
Aviation Warning Light conforms to ICAO annexure-14,chapter 6 under Low
Intensity type “A”
7.
LED flash head operated
through reliable power supply, with a dedicated photo-sensing device for night
mode operation.
8.
The light housing is made
of aluminum casting for all weather protection and humidity resistance.
9.
Lens is made from fine
quality glass.
10.
All exposed hardware is
made of non corrosive materials.
Technical
Specification
Input power
supply : 220V 50Hz,Single Phase
Intensity
: >10 cd
Beam
Pattern : Circular
Flash Rate
: 30 to 60 FPM adjustable depend
Upon customer
requirement
Flash head
a) Weight
: 3 Kg
b) Wind
load : 150 mph(240kph)
Atmospheric
Condition
Operating
temperature : -20°C t0 + 55°C
Humidity : 95% relative humidity
Environment
Protection : IP65 (For light)
IP55 (Control box)
Rated lamp
life : 50,000 hours (apprx.)
Wind
pressure : Up to 150 mph (240kph)
Resistance
Corrosion : All parts are corrosion –resistant.
Moisture
: The fixture is moisture proof.
Special Price =
7,500.-Bht.
Specification
This subsection
provides specification for the Low Intensity Aviation Obstruction Light.
Rated Lamp life
The rated lamp
life for Low Intensity Aviation Obstruction Light is approximately 50,000 hours.
Environmental Operating
Conditions
The Low Intensity
Aviation Obstruction Light is designed to operate under the conditions presented
below for temperature, relative humidity, and wind.
Temperature
-20°C t0 + 60°C
Salient
Features of system
1.
Low intensity as per ICAO
2.
(International Civil
Aviation Organization) and FAA (Federation Aviation Administration) standard.
3.
Easy installation.
4.
Surge protection from
external atmospheric conditions.
5.
Self-protection of
equipment and personnel on work.
6.
Omni-directional LED
Aviation Warning Light conforms to ICAO annexure-14,chapter 6 under Low
Intensity type “A”
7.
LED flash head operated
through reliable power supply, with a dedicated photo-sensing device for night
mode operation.
8.
The light housing is made
of steel casting for all weather protection and humidity resistance.
9.
Lens is made from fine
quality glass.
10.
All exposed hardware is
made of non corrosive materials.
Technical Specification
Solar
module : 5 watts
Solar panel
dimension: 300x285 cm.
Battery
: 4.0 ah 10vdc.
Peak Intensity
: > 13.5 cd.
Vertical
Divergence : +/3 10 degree
Temperature
arrange : -30°C - +55°C
Warranty
3 years LED lamps ,
2 years for battery
LED. Lamp
Input power
supply
: 12 Vdc.
Intensity :
>10 cd
Beam
Pattern : Circular
Flash
Rate : 30 to 60 FPM
adjustable
Flash head
a)
Weight : 3 Kg
b) Wind
load : 150 mph(240kph)
Atmospheric
Condition
Operating
temperature : -20°C t0 + 55°C
Humidity : 95% relative
humidity
Environment
Protection : IP65
Rated lamp
life : 50,000 hours (apprx.)
Wind
pressure : Up to 150 mph (240kph)
Resistance
Corrosion : All parts are corrosion –resistant.
Moisture
: The fixture is moisture proof.
OPRERATION
Only qualified
personnel,physically capable of operating the equipment and with no impairments
in their judgment or reaction times , should operate this equipment.
Before starting this
equipment, check all safety interlocks, fire-detection system, and protective
device such as panels and covers. Make sure all devices are fully functional. Do
not operate the system if these devices are not working properly. Do not
deactivate or bypass automatic safety interlocks or locked-out electrical
disconnects.
Never operate equipment
with a known malfunction.
Do not attempt to operate
or service electrical equipment if standing water is present.
Use this equipment only
the environments for which it is rated, Do not operate this equipment in humid,
flammable, or explosive environments unless it has been rated for safe operation
in these environments.
Never touch exposed
electrical connections on equipment while the power is ON.
|